EC-450

All features at a glance
• Basic Lab pH/cond. combi-meter
for pH, mV, conductivity, TDS and
temperature
• automatic temperature compensation
• huge display for simoultaneous readouts
• up to 5-point calibration with automatic
buffer recognition
• data memory up to 100 datas
• electrode arm can be used on either side
• slide-out quick reference guide
• 3 years warranty
|
 |
|
EC-470

All features at a glance
•Standard Lab pH/conductivity meter for pH,
mV, conductivity, TDS, salinity,
resistance and temperature
• 4-cell conductivity electrode
• automatic temperature compensation
• huge, backlit grafic display
• GLP-function
• Set up is password protected
• up to 6-point calibration with automatic
buffer recognition
• GLP-memory for 500 datas with
autolog-function
• alarm when calibration is due
• bi-directional RS 232-interface
• electrode arm can be used on either side
• slide-out quick reference guide
• 3 years warranty
|
 |
|
Various sets are available:
EC-450-SE Lab bench pH/conductivity meter with arm, pH-electrode ECE-pH 50 and conductivity cell
EC-470-SE Lab bench pH/conductivity meter with backlit grafic display, arm, pH-electrode ECE-pH 60, 4-cell conductivity electrode, data memory, GLP-function, RS 232-interface
|
|
Model
Measuring range pH
Accuracy (pH)
Measuring range cond.
Accuracy conductivity
Measuring range TDS
Accuracy TDS
Measuring range temp. Calibration
Power supply
Input pH-electrode
Input conductivity cell
|
EC-450
0,00 - 14,00
0,01
0,1 µS - 200,0 mS 1 % fullscale, +/- 1 digit
0,1mg/l – 200,0g 1 % fullscale, +/- 1 digit
0,0 - 100,0 °C up to 5-point AC-adapter, 9 V DC
BNC
8 Pin DIN
|
EC-470
-2,000-20,000
0,1/0,01/0,001
0,05 µS - 500,0 mS 1 % fullscale, +/- 1 diget
0,05mg/l – 500,0g 1 % fullscale, +/- 1 digit
0,0 - 100,0 °C
up to 6-point
AC-adapter, 9 V DC
BNC
8 Pin DIN
|
|
Downloads (PDF)
|
|
Katalog Elektrochemie
|
|
Accessories
|
 |
|
 |
|
 |
ECE-pH 50
pH-electrode with epoxy body, gel filled
12 x 110 mm, 1 m cable with BNC
|
|
ECE-pH 60
pH-glas electrode with double-diaphragma
12 x 110 mm, 1 m cable with BNC
|
|
ECE-pH 95 Temperature sensor for EC 150/170
|
 |
|
 |
|
 |
ECE-pH 4-1
Buffer, 250 ml, ph 4
|
|
ECE-pH 4-3
Buffer, 1.000 ml, ph 4
|
|
ECE-pH 7-1 Buffer, 250 ml, ph 7
|
 |
|
 |
|
 |
ECE-pH 7-3
Buffer, 1.000 ml, ph 7
|
|
ECE-pH 10-1
Buffer, 250 ml, ph 10
|
|
ECE-pH 10-3
Buffer, 1.000 ml, ph 10
|
|
|
 |
|
 |
|
|
ECE-LF 70
4-cell conductivity electrode with temperature sensor for EC 270 and EC 470
|
|
ECE-LF 10
0,01 M KCL-calibration solution, 250 ml
|
|
|
|
|
|
|

|
|