EC-40 multi

All features at a glance
• Display pH/mV and Temperature, COND/TDS and Temperature
simultaneously • Resolution: 0,1/0,01 pH; Auto range for
Cond
• Selectable cell constant allows for
use with 2 plate cell
• Large 2 color display with indication
of Calibration Buffers and
measurement’s stability
• Indication stability of the measurement
with icon
• Intrument can be delievred with a
magnetic stirrer
• IP54 protection
• 3 years instrument warranty
|
 |
|
|
EC-45 multi

zusätzlich beim EC-45 multi
• Display pH/mV and Temperature,
COND/TDS/Salinity/Resistivity
and Temperature simultaneously • Selectable Resolution:
0,1/0,01/0,001 pH;
Auto range for COND
• GLP and IQ-OQ manual available
• Selectable cell constant allows for
use with 2 or 4 plate cell
• Memory with re-call of last calibration
date and time and information
of electrode’s life
• CAL DUE: set of calibration frequency
for high quality of measurements
• Stability Parameter (Low-Med-High)
for high accuracy measurement • Non-volatile memory holds up to
1000 data points with date and
time in automatic
(Data logger) or manual
• 2x USB ports to transfer data at PC
or printer and for external keyboard
• Software PC-Link to download data
(included)
|
 |
|
Professional Benchtop Multi Meter EC-40 multi • EC-45 multi
The large color display easy on to read shows all information necessary information about measurement, calibra- tion, standards, cell condition, GLP. Anyone can use this meter easily with its intuitive menu available in up to 8 languages in the EC-45-Multi. Easy to learn.
Up to 5-point pH-calibration and up to 4-point Conductivty calibration with automatic recognition of all standards. Icon support for all calibration functions and advanced electrode diagnostics. Easy to calibrate
All functions can be controlled in an intuitive and easy way. Both instruments can be delivered with a stirrer.
|
|
Technical data
pH meas. Range
Resolution
Calibration points
Buffer recognized
mV meas. Range/Resolution
Cond. Measuring range
Resolution cond
Relative accuracy
TDS Measuring range
TDS factor
Relative Accuracy
Temperature range
Accuracy/Resolution Temp.
Temperature compensation
Temperature calibration
Calibration points Cond.
Calibration standards recognized
Indication of cell condition
GLP
CALDUE
Memory
Inputs
Protection class
Power supply
Dimensions
Weight
|
EC-40 multi
0-14
0.1 / 0.01 / ±0,01
1 bis 3
USA, NIST,
2 x user defined
±2000/ 0,1/1
0,00 – 200
Automatic scale
±0,5 % value reading
0,1mg/l...100 g/l
0.40...1.00
±0,5 % value reading
0 – 100
0,1/±0,2
Manal or autom.
Yes
1 bis 4
84, 1413 µS / 12.88,
111.8 mS, benutzerdef.
Yes
No
No
No
2xBMC, 2xATC
IP 54
AC/DC adapter
9V 300 mA
200 x 220 x 100 mm
950 g
|
EC-45 multi
-2-20
0.1 / 0.01 / 0.001
1 bis 4
USA, NIST, 5 x user defined
±2000/ 0,1/1
0,00....1000
Automatic scale
±0,5 % value reading
0,1mg/...500 g/l
0.40...1.00
±0,5 % value reading
-20 – 200
0,1/±0,2
Manal or autom.
Yes
1 bis 4
84, 1413 µS / 12.88,
111.8 mS, benutzerdef.
Yes
Yes, date/time
Yes
Ja, 1000 Data
2xBMC, 2xATC
2 x USB
IP 54
AC/DC adapter
9 V / 300 mA
200 x 220 x 100 mm
950 g
|
|
Erhältliche Set-Varianten:
EC-40 multi 0
Kit without pH electrode and cell, with cable S7/BNC, temp. probe NT55, pH buffer solution pH 7, pH 4, conductivity solution 1413 μS and 12,88 mS, power supply and accessories
EC-40 multi 1
Kit included pH electrode XS Polymer, cell 2301T with ATC. Cable S7/BNC, pH buffer solution pH 7 and pH 4, conductivity solution 1413 μS and 12,88 mS, power supply and accessories
EC-45 multi 0
Kit without pH electrode and cell, with cable S7/BNC, temp. probe NT55, pH buffer solution pH 7 and pH 4, conductivity solution 1413 μS and 12,88 mS, power supply and accessories
EC-45 multi 1
Kit included pH electrode XS STANDARD S7, cell 2301T with ATC. Cable S7/BNC, pH buffer solution pH 7 and pH 4, conductivity solution 1413 μS and 12,88 mS, power supply and accessories
All kits are also avilable with magnetic stirrer.
|
Downloads (PDF)
|
|
|
|

Catalog Elektrodes
and Accessories
|

Catalog Elektrochemistry
|
|

|
|